View Source:
Bird Electronic Corporation
Note:
You are viewing an old revision of this page.
View the current version.
!!! Bird Electronic Corporation ! Manuals * [Model 43 Wattmeter|Upload:/HaroldHallikainen/BirdModel43.pdf] * Model 67 Termination Wattmeter * [Additional Instructions|Upload:harold/67 WATTMETER.pdf] * [Additional Instructions for 67C|Upload:harold/67C WATTMETER Addendum.pdf] * [Model 80 Series|Upload:harold/80 SERIES LOAD RESISTOR.pdf] 50 ohm Load Resistor * [80A|Upload:harold/80A.pdf] - 20 Watt 50 ohm Load Resistor * [80AS1|Upload:harold/80AS1.pdf] - 20 Watt Liquid Cooled 50 ohm Load Resistor * [Model 81|Upload:harold/81.pdf] - 50 Watt Coaxial Load Resistor * [Model 81B|Upload:harold/81B.pdf] - 80 Watt Coaxial Load Resistor * [Model 502|Upload:harold/502 RF Load Instructions.pdf] - 25 kW Water Cooled Coaxial Load Resistor * [Model 502 and 890 Field Installation of Resistor and Housing|Upload:harold/502 - 890 RF LOAD RESISTOR.pdf] * [Models 611, 612, 61, 67, and 67C|Upload:harold/611 - 612 - 61 - 67 - 67C RF Wattmeters.pdf] RF Wattmeters * [Model 640|Upload:harold/640 PEAK WATTMETER.pdf] - Peak Reading Wattmeter * [Model 670|Upload:harold/670 WATTMETER.pdf] - 500 Watt Terminating Wattmeter * [Model 693|Upload:harold/693 WATTMETER TS-118A_AP.pdf] (TS-118A) 400 Watt Terminating Wattmeter. Uses thermocouple to measure RF voltage. * [Model 694|Upload:harold/694 WATTMETER.pdf] 1 kW Terminating Wattmeter, 2 - 30 MHz. * [Model 883|Upload:harold/883 LOAD 1 KW.pdf] 1 kW Coaxial Resistor, DC to 2.5 GHz. * [Model 884|Upload:harold/884 LOAD 1 KW.pdf] 1 kW Coaxial Resistor, DC to 3.3 GHz * [Model 887|Upload:harold/887 LOAD 1 KW.pdf] 1.2 kW Coaxial Resistor, DC to 2.5 GHz * [Model 888|Upload:harold/888 LOAD 1 KW.pdf] 1.2 kW Coaxial Resistor, DC to 2.5 GHz * [Model 889|Upload:harold/889 LOAD 50 KW.pdf] 50 kW RF Load, DC to 220 MHz * [Model 3122 and 4342|Upload:harold/3122_4342.pdf] Thruline Dual Needle Directional RF Wattmeter. 1W to 10 kW, 2 MHz to 2.3 GHz. Model 3122 is 19 inch rack mount. The 4342 is portable. * [Model 3126, 3127, 3128|Upload:harold/3126 - 27 - 28 WATTCHER RF MONITOR - ALARM.pdf] Wattcher RF Monitor/Alarm. * [Model 3142|Upload:harold/3142 POWER REDUCTION TEST SET.pdf] Power Reduction Test Set. 1 kW PEP, 250 W average. Includes RF wattmeter (50 W and 1 kW full scale) and attenuated output ( 0 to 15 dB). * [Model AT-100|Upload:harold/920-at100.pdf] Antenna Tester. Measures VSWR, Return Loss, Rho, and relative field strength 2 to 136 MHz. * [Model 3170, 3171, 3172, 3173|Upload:harold/3170_71 HIGH SPEED WATTCHER.pdf] Thruline High Soeed Wattcher. 100 mW to 250 kW. * [Model 3180|Upload:harold/3180 FM DEVIATION INDICATOR.pdf] FM Deviation Indicator. Thruline coupler with 50 MHz FM receiver. * [Model 3316A|Upload:harold/3316A FILTER COUPLER.pdf] Filter Coupler to measure peak output power of [TACAN|https://en.wikipedia.org/wiki/Tactical_air_navigation_system] transmitters. * [Model 3900|Upload:harold/3900 FREQUENCY COUNTER WATTMETER.pdf] Frequency Counter / Wattmeter * [Model 4029|Upload:harold/4029 POWER SENSOR CALIBRATOR.pdf] Power Sensor Calibrator. Used to set calibration factors for different frequencies in the 4020 series power sensors. * [Model 4030|Upload:harold/4030 RELATIVE FIELD STRENGTH ELEMENT.pdf] Relative Field Strength Element. Plugs into model 43, 4430, or 4431 wattmeter and drives the wattmeter's meter with a current proportional to the received RF field. The element has a small antenna and is sensitive to 1 MHz to 1 GHz. 1 watt at 150 MHz 8 feet away will cause full scale deflection. * [Model 4110 Series|Upload:harold/4110-- - RF TEST SET.pdf] RF Test Set. A meter and thruline screwed together. By choosing elements, measurements from 2 to 76 MHz and 5 to 100 watts can be made. * [Model 4111 Series|Upload:harold/4111 THRULINE WATTMETER.pdf] Thruline Wattmeters. Models 4111, 4112, 4113, 4114, 4115, 4116, 4118, and 4120 cover 50 watts to 1.26 kW over various ranges between 2 to 512 MHz. * [Model 4127|Upload:harold/4127 RF TEST SET FOR AN PRC-70 RADIO.pdf] RF Test Set for [AN/PRC-70|http://www.greenradio.de/e_prc70.htm] radio. Thruline meter with termination. 2 to 76 MHz. 5 watts to 40 watts full scale. Termination rated at 15 watts continuous or 40 watts intermittent (2 minutes on, 10 minutes off). * [Model 4130|Upload:harold/4130 TACTICAL RADIO TEST SET.pdf] Tactical Radio Test Set. Includes a thruline wattmeter from 0.5 to 100 watts between 30 and 90 MHz. Also includes an RF generator that is frequency modulated. The outputs are every 5 MHz from 30 MHz to 90 MHz and at a level of 0.45 uV. Finally, the 4130 can measure relative field strength. * [Model 4130B|Upload:harold/4130B TEST SET DATA SHEET.pdf] - Same as [Model 4130|Upload:harold/4130 TACTICAL RADIO TEST SET.pdf] except uses 8 D cells instead of a 9V battery. * [Model 4131|Upload:harold/4131 OPERATING INSTRUCTIONS.pdf] Tactical Radio Test Set. Tests 30 to 90 MHz FM transceivers. Includes frequency counter, wattmeter with load, and frequency modulated 0.5 uV RF output every 5 MHz from 30 MHz to 90 MHz. A 50 MHz FM demodulator is included, along with a relative field strength meter. * [Model 4159|Upload:harold/4159 THRULINE DIRECTIONAL WATTMETER.pdf] OEM thruline wattmeter. 225 to 400 MHz, 250 W. * [Model 4198|Upload:harold/4198 THRULINE DIRECTIONAL RF PROBE.pdf] OEM Thruline Directional RF Probe. 40 mW to 2 W. 4.4 to 5 GHz. * [Model 4201 Series|Upload:harold/4201 MULTI-CHANNEL RF WATTMETER.pdf] Multichannel RF Wattmeter. Input selector switches select one of 12 or 24 Thruline sensors to drive the forward and reflected meters. * [Model 4301 Instructions Addendum|Upload:harold/4301-ADDENDUM TO 4301 INSTRUCTIONS.pdf] * [Model 4307|Upload:harold/4307 WATTMETER.pdf] Thruline RF Wattmeter, 75 ohms, 2 MHz to 1 GHz, 25 W to 5 kW. the meter and sample can be separated by up to 3 feet for installed applications. * [Model 4310|Upload:harold/4310 PEAK READING WATTMETER.pdf] Peak Reading RF Wattmeter. 50 ohms, 50 W to 10 kW. 2 MHz to 1.26 GHz. An adjustable DC bias is applied in series with the diode detecting the RF. The resulting demodulated RF plus DC is observed on an oscilloscope. As the DC bias is adjusted, the lower power portion of the waveform on the scope disappears. The variable DC voltage drives the meter calibrated in watts. The power at any portion of the waveform can be determined. * [Model 4311 - 4314|Upload:harold/4311-4314 WATTMETER.pdf] Thruline RF Wattmeter. 1 W to 10 kW average or peak. 450 kHz to 2.3 GHz. * [Models 4320, 4321|Upload:harold/4320-21 PEAK READING AMPLIFIERS.pdf] Peak Reading Amplifiers. Place between Thruline sensor and model 43 meter to detect peak power instead of average power. * [Model 4324|Upload:harold/4324 PEAK READING WATTMETER.pdf] Peak Reading Wattmeter. * [Model 4337 Addendum|Upload:harold/4337-ADDENDUM TO 43 BOOK.pdf] to [Model 43 Wattmeter|Upload:/HaroldHallikainen/BirdModel43.pdf]. Changes from 50 ohms to 75 ohms. * [Models 4340, 4341|Upload:harold/4340 - 41 LAB STANDARD WATTMETER.pdf] Laboratory Standard RF Wattmeter. 2 MHz to 1 GHz. 100 W. 50 ohms. * [Model 4345|Upload:harold/4345 WATTMETER.pdf] Peak Reading Wattmeter. 950 MHz to 1.3 GHz. 50 ohms. 250 W to 5 kW. * [Model 4350 Series|Upload:harold/4350 -HAM-MATE- SERIES WATTMETER.pdf] ~HamMate Directional RF Wattmeter. 1.8 to 30 MHz or 50 to 150 MHz. 1,000, 2,000, or 400 watts * [Model 4370|Upload:harold/4370 -HAM-MATE-.pdf] ~HamMate Directional RF Wattmeter. 10, 25, 100, 500 watts full scale. 25 to 520 MHz. * [Model 4371|Upload:harold/4371 THRULINE WATTMETER.pdf] Thruline Wattmeter with digital display. 25 to 520 MHz. 1, 10, 100 watts full scale. * [Model 4380 Series|Upload:harold/4380 RF POWER ANALYST.pdf] Power Analyst. Microprocessor based instrument that reads forward and reflected power (peak or average) and amplitude modulation percentage. Through the use of different plug in elements, it measures 100 mW to 250 kW (across the various models in the series). 450 kHz to 2.3 GHz across the models in the series. * [Model 4380A-232|Upload:harold/4380A-232 BUS COMPATIBLE POWER ANALYST.pdf] RS232 Interface box for [Model 4380 Series|Upload:harold/4380 RF POWER ANALYST.pdf] Power Analyst. Interfaces with [Model 4380 Series|Upload:harold/4380 RF POWER ANALYST.pdf] Power Analyst through 15 pin plug that includes keyboard and multiplexed BCD data. Uses ASCII commands over RS232. Also includes logging at set interval, though only one value is saved (value must be read by external computer before next reading is captured). * [Model 4380A-488|Upload:harold/4380A-488 BUS COMPATIBLE INTERFACE.pdf] IEEE 488 Interface box for [Model 4380 Series|Upload:harold/4380 RF POWER ANALYST.pdf] Power Analyst. Interfaces with [Model 4380 Series|Upload:harold/4380 RF POWER ANALYST.pdf] Power Analyst through 15 pin plug that includes keyboard and multiplexed BCD data. Uses ASCII commands over IEEE 488. Also includes logging at set interval, though only one value is saved (value must be read by external computer before next reading is captured). * [Model 4391|Upload:harold/4391RF POWER ANAYLST.pdf] Multipurpose Thruline Wattmeter Power Analyst. Based on plug in elements, the system measures 450 kHz to 2.3 GHz at powers of 100 mW to 10 kW. * [Model 4410|Upload:harold/4410 RF WATTMETER.pdf] RF Directional Wattmeter Test Set. With different elements, the instrument covers 200 kHz to 2.3 GHz. * [Model 4410P|Upload:harold/4410 P PANEL MOUNTED WATTMETER.pdf] Panel mount version of the [Model 4410|Upload:harold/4410 RF WATTMETER.pdf]. * [Model 4411|Upload:harold/4411- ADDENDUM TO 4410 BOOK.pdf] - [Model 4410|Upload:harold/4410 RF WATTMETER.pdf] but with AC or battery operation. * [Model 4420|Upload:harold/4420 RF POWER METER.pdf] Microprocessor controlled power meter with analog meter. Linearization and calibration data is stored in the power sensor modules (4020 series). * [Model 421-110|Upload:harold/4421-110 POWER METER.pdf] Power Meter * [Model 4421-488 Programming Card|Upload:harold/4421-488 PROGRAMMING INFO.pdf] * [Model 4450|Upload:harold/4450 RF WATTMETER.pdf] Thruline Wattmeter. Designed for measuring power in power line carrier systems. Measures up to 100 watts at 20 kHz to 1 MHz. * [Model 4600 and 4800 Specifications|Upload:harold/4600-4800 SPECIFICATIONS.pdf] * [Model 4640 and 4840|Upload:harold/4640_4840 ADDENDUM TO 4600-4800 BOOK.pdf] - Same as [Model 4600 and 4800|Upload:harold/4600-4800 SPECIFICATIONS.pdf] except the [Model 4640 and 4840|Upload:harold/4640_4840 ADDENDUM TO 4600-4800 BOOK.pdf] are designed for 4 1/16 inch rigid line instead of 3 1/8 inch line. * [Model 4700 Series|Upload:harold/4700 RF WATTMETER.pdf] Thruline Wattmeters for 1 5/8 inch line. Depending on model, covers 2 MHz to 1 GHz, up to 25 kW. * [Model 4900|Upload:harold/4900 RF WATTMETER.pdf] Thruline RF Wattmeter. 2 to 100 MHz, up to 250 kW. 6 1/8 inch line. * [Model 5000|Upload:harold/5000 DIGITAL RF WATTMETER.pdf] Digital RF Power Meter. * [Model 5000-EX|Upload:harold/5000-EX DIGITAL RF WATTMETER.pdf] Digital RF Power Meter. * [Model 6010|Upload:harold/6010 HI-POWER RF CALORIMETER.pdf] High Power RF Calorimeter. 15 kW to 50 kW, DC to 1.3 GHz. * [Model 6020|Upload:harold/6020 HI-POWER RF CALORIMETER.pdf] High Power RF Calorimeter. 1.2 kW, DCto 3.5 GHz. * [Model 6030|Upload:harold/6030 Hi-Power RF Calorimeter.pdf] High Power RF Calorimeter. 10 kW, 1.4 GHz. * [Model 6070|Upload:harold/6070 Hi-Power RF Calorimeter.pdf] High Power RF Calorimeter. 5 kW, DC to 2 GHz. * [Model 6080A, 6081A|Upload:harold/6080 - 6081A RF Calorimeter.pdf] RF Calorimeter. * [Model 6090|Upload:harold/6090 RF DIGITAL CALORIMETER.pdf] Digital RF Calorimeter. 1 kW, 3.5 GHz. * [Model 6091|Upload:harold/6091 - 6091P RF POWER CALORIMETER.pdf] RF Calorimeter. * [Model 6100 Series|Upload:harold/6100 Series RF WATTMETERS 611 - 612 - 61.pdf] Termaline RF Wattmeter. 30 MHz to 1 GHz, 80 watts. [Another version|Upload:harold/6100 Series RF WATTMETERS.pdf] * [Model 6104|Upload:harold/6104 RF WATTMETERS.pdf] Termaline RF Wattmeter. * [Models 6104, 6154, 6155, 6156|Upload:harold/6104 - 6154 - 6155 - 6156 RF WATTMETER.pdf] RF Wattmeter specifications and replacement parts list. * [Model 6140|Upload:harold/6140T-879 RF WATTMETER.pdf] Terminating RF Wattmeter. Uses RF voltmeter to measure power instead of Thru Line element. ---- Back to HomePage<br> Contribute Documents? <?plugin UpLoad ?>
BroadcastHistory
HomePage
How to use this Wiki
Adding Pages
List all Categories
Main Categories
CategoryWikiPlugin
CategoryActionPage
Search
Toolbox
Recent Changes
Recent New Pages
What links here
All pages
Recent Changes
RecentChangesCached
Tape Cartridge History
Favorite Categories
WikiPlugin
(140)
ActionPage
(77)
InterWiki
(18)
InterWiki
(18)
View Page
View Source
History
Diff
Sign In