Bird Electronic Corporation
Note: You are viewing an old revision of this page. View the current version.
Bird Electronic Corporation
Manuals
- Model 43 Wattmeter
Model 67 Termination Wattmeter
Model 80 Series 50 ohm Load Resistor
- Model 81 - 50 Watt Coaxial Load Resistor
- Model 81B - 80 Watt Coaxial Load Resistor
Model 502 - 25 kW Water Cooled Coaxial Load Resistor
- Models 611, 612, 61, 67, and 67C RF Wattmeters
- Model 640 - Peak Reading Wattmeter
- Model 670 - 500 Watt Terminating Wattmeter
- Model 693 (TS-118A) 400 Watt Terminating Wattmeter. Uses thermocouple to measure RF voltage.
- Model 694 1 kW Terminating Wattmeter, 2 - 30 MHz.
- Model 883 1 kW Coaxial Resistor, DC to 2.5 GHz.
- Model 884 1 kW Coaxial Resistor, DC to 3.3 GHz
- Model 887 1.2 kW Coaxial Resistor, DC to 2.5 GHz
- Model 888 1.2 kW Coaxial Resistor, DC to 2.5 GHz
- Model 889 50 kW RF Load, DC to 220 MHz
- Model 3122 and 4342 Thruline Dual Needle Directional RF Wattmeter. 1W to 10 kW, 2 MHz to 2.3 GHz. Model 3122 is 19 inch rack mount. The 4342 is portable.
- Model 3126, 3127, 3128 Wattcher RF Monitor/Alarm.
- Model 3142 Power Reduction Test Set. 1 kW PEP, 250 W average. Includes RF wattmeter (50 W and 1 kW full scale) and attenuated output ( 0 to 15 dB).
- Model AT-100 Antenna Tester. Measures VSWR, Return Loss, Rho, and relative field strength 2 to 136 MHz.
- Model 3170, 3171, 3172, 3173 Thruline High Soeed Wattcher. 100 mW to 250 kW.
- Model 3180 FM Deviation Indicator. Thruline coupler with 50 MHz FM receiver.
- Model 3316A Filter Coupler to measure peak output power of TACAN transmitters.
- Model 3900 Frequency Counter / Wattmeter
- Model 4029 Power Sensor Calibrator. Used to set calibration factors for different frequencies in the 4020 series power sensors.
- Model 4030 Relative Field Strength Element. Plugs into model 43, 4430, or 4431 wattmeter and drives the wattmeter's meter with a current proportional to the received RF field. The element has a small antenna and is sensitive to 1 MHz to 1 GHz. 1 watt at 150 MHz 8 feet away will cause full scale deflection.
- Model 4110 Series RF Test Set. A meter and thruline screwed together. By choosing elements, measurements from 2 to 76 MHz and 5 to 100 watts can be made.
- Model 4111 Series Thruline Wattmeters. Models 4111, 4112, 4113, 4114, 4115, 4116, 4118, and 4120 cover 50 watts to 1.26 kW over various ranges between 2 to 512 MHz.
- Model 4127] RF Test Set for AN/PRC-70 radio. Thruline meter with termination. 2 to 76 MHz. 5 watts to 40 watts full scale. Termination rated at 15 watts continuous or 40 watts intermittent (2 minutes on, 10 minutes off).
Back to HomePage
Contribute Documents?